May 2006
11
MIC280
MIC280
Micrel
using the A.R.A. if the host system does not implement the
A.R.A protocol. Figure 4 and Figure 5 illustrate these two
methods of responding to MIC280 interrupts.
Since temperature-to-digital conversions continue while /INT
is asserted, the measured temperature could change between
the MIC280s assertion of /INT and the hosts response. It
is good practice for the interrupt service routine to read the
value in TEMPx, to verify that the over-temperature or under-
temperature condition still exists. In addition, more than one
temperature event may have occurred simultaneously or in
rapid succession between the assertion of /INT and servic-
ing of the MIC280 by the host. The interrupt service routine
should allow for this eventuality. At the end of the interrupt
service routine, the interrupt enable bits should be reset to
permit future interrupts.
Reading the Result Registers
All MIC280 registers are eight bits wide and may be accessed
using the standard Read_Byte protocol. The temperature
result for the local zone, zone 0, is a single 8-bit value in
register TEMP0. A single Read_Byte operation by the host
is sufcient for retrieving this value. The temperature result
for the remote zone is a twelve-bit value split across two
eight-bit registers, TEMP1h and TEMP1l. A series of two
Read_Byte operations are needed to obtain the entire twelve-
bit temperature result for zone 1. It is possible under certain
conditions that the temperature result for zone 1 could be
updated between the time TEMP1l or TEMP1h is read and
the companion register is read. In order to insure coherency,
TEMP1h supports the use of the Read_Word protocol for ac-
cessing both TEMP1h and TEMP1l with a single operation.
This insures that the values in both result registers are from
the same ADC cycle. This is illustrated in Figure 3 above.
Read_Word operations are only supported for TEMP1h:
TEMP1l, i.e., only for command byte values of 01h.
Polling
The MIC280 may either be polled by the host, or request
the hosts attention via the /INT pin. In the case of polled
operation, the host periodically reads the contents of STA-
TUS to check the state of the status bits. The act of reading
STATUS clears it. If more than one event that sets a given
status bit occurs before the host polls STATUS, only the fact
that at least one such event has occurred will be apparent
to the host. For polled systems, the global interrupt enable
bit should be clear (IE = 0). This will disable interrupts from
the MIC280 (prevents the /INT pin from sinking current).
For interrupt-driven systems, IE must be set to enable the
/INT output.
Shutdown Mode
Putting the device into shutdown mode by setting the shutdown
bit in the conguration register will unconditionally deassert
/INT, clear STATUS, and purge the fault queues. Therefore,
this should not be done before completing the appropriate
interrupt service routine(s). No other registers will be affected
by entering shutdown mode. The last temperature readings
will persist in the TEMPx registers.
The MIC280 can be prevented from entering shutdown
mode using the shutdown lockout bit in the lock register. If
L3 in LOCK is set while the MIC280 is in shutdown mode,
it will immediately exit shutdown mode and resume normal
operation. It will not be possible to subsequently re-enter
shutdown mode. If the reset bit is set while the MIC280 is
shut down, normal operation resumes from the reset state.
(see below)
Warm Resets
The MIC280 can be reset to its power-on default state during
operation by setting the RST bit in the conguration register.
When this bit is set, /INT will be deasserted, the fault queues
will be purged, the limit registers will be restored to their normal
power-on default values, and any A/D conversion in progress
will be halted and the results discarded. This includes reset-
ting bits L3 - L0 in the security register, LOCK. The state of
the MIC280 following this operation is indistinguishable from
a power-on reset. If the reset bit is set while the MIC280 is
shut down, the shutdown bit is cleared and normal operation
resumes from the reset state.
If bit 4 of LOCK, the Warm Reset Lockout Bit, is set, warm
resets cannot be initiated, and writes to the RST bit will be
completely ignored. Setting L4 while the MIC280 is shut
down will result in the device exiting shutdown mode and
resuming normal operation, just as if the shutdown bit had
been cleared.
EVENT
CONDITION
MIC280 RESPONSE*
Data ready
A/D conversions complete for both zones; result
Set S7, clear IM7, assert /INT
 
registers updated; state of /INT updated
Over-temperature, remote
([TEMP1h:TEMP1l]) > CRIT1
Set S1, assert /INT
Over-temperature, local
TEMP0 > CRIT0
Set S0, assert /INT
High temperature, remote
([TEMP1h:TEMP1l]) > THIGH1h:THIGH1l]**
Set S4, clear IM4, assert /INT
High temperature, local
TEMP0 > THIGH0**
Set S6, clear IM6, assert /INT
Low temperature, remote
( [TEMP1h:TEMP1l]) < TLOW1h:TLOW1l]**
Set S3, clear IM3, assert /INT
Low temperature, local
TEMP0 < TLOW0**
Set S5, clear IM5, assert /INT
Diode fault
T1 open or T1 shorted to VDD or GND
Set S2, clear IM2, assert /INT
* Assumes interrupts enabled. **CONDITION must be true for Fault_Queue conversions to be recognized.
Table 6: MIC280 Temperature Events
相关PDF资料
MIC2800-GFSYML TR IC REG TRPL BUCK/LINEAR 16MLF
MIC281-7BM6 TR IC SUPERVISOR THERMAL SOT23-6
MIC2810-1JGMYML TR IC REG TRPL BUCK/LINEAR 16MLF
MIC284-2BMM TR IC SUPERVISOR THERM 2ZONE 8-MSOP
MIC3385-1.5YHL TR IC REG DL BCK/LINEAR SYNC 14-MLF
MIC384-1YMM IC SUPERVISR THERM LOC/REM 8MSOP
MIC5158BN IC REG CTRLR SGL FIX/ADJ 14-DIP
MIC5159BM6 TR IC REG CTRLR SGL POS ADJ SOT23-6
相关代理商/技术参数
MIC280-7BM6TS 制造商:Rochester Electronics LLC 功能描述:- Bulk
MIC2807-JJYML TR 功能描述:PMIC 解决方案 PAM Power Management IC: DAC controlled DC-DC + 2 LDOs RoHS:否 制造商:Texas Instruments 安装风格:SMD/SMT 封装 / 箱体:QFN-24 封装:Reel
MIC2807-MMYML 制造商:Rochester Electronics LLC 功能描述: 制造商:RF Micro Devices Inc 功能描述: 制造商:Micrel Inc 功能描述:
MIC2807-MMYML TR 功能描述:PMIC 解决方案 PAM Power Management IC: DAC controlled DC-DC + 2 LDOs RoHS:否 制造商:Texas Instruments 安装风格:SMD/SMT 封装 / 箱体:QFN-24 封装:Reel
MIC2807-MMYML-TR 功能描述:RF IC PA Management IC CDMA2000, UMTS/WCDMA 2MHz W/DAC Input and Bypass Switch 17-MLF? (2.5x2.8) 制造商:microchip technology 系列:- 包装:剪切带(CT) 零件状态:有效 功能:PA 管理 IC 频率:2MHz RF 类型:CDMA2000,UMTS/WCDMA 辅助属性:W/DAC 输入和旁路开关 封装/外壳:17-VFQFN,17-MLF? 供应商器件封装:17-MLF?(2.5x2.8) 标准包装:1
MIC2807-NGYML 制造商:RF Micro Devices Inc 功能描述:
MIC2807-NNYML 制造商:Rochester Electronics LLC 功能描述: 制造商:RF Micro Devices Inc 功能描述:
MIC2807-NNYML TR 功能描述:PMIC 解决方案 PAM Power Management IC: DAC controlled DC-DC + 2 LDOs RoHS:否 制造商:Texas Instruments 安装风格:SMD/SMT 封装 / 箱体:QFN-24 封装:Reel